Skip to main content
Open Thermal AI
Menu
    • Real Cases
    • Learn Heat Pumps
    • Project Center
    • Professional Support
    • About & Impact
Evaluate a Project
    • Real Cases
    • Learn Heat Pumps
    • Project Center
    • Professional Support
    • About & Impact
Evaluate a Project
Home / Articles

IEA HPT TCP · Annex 58

Annex 58 Task Digest

Curated takeaways · key schematics · free official PDFs 策划提炼 · 主图示意 · 官方免费 PDF

Annex 58 (2020–2023) maps high-temperature heat pumps that supply useful heat above ~100 °C. Below: distilled takeaways for Task 1–5, with 7 self-drawn schematics based on the reports’ main figures (not PDF copies). Scroll each Task section for its chart(s). Downloads: Useful links. Advisory spine: Services. Follow-on: Annex 68.

Annex 58(2020–2023)梳理可提供约 100°C 以上有用热的工业高温热泵。下文为 Task 1–5 策划提炼,共 7 张自绘主图(非 PDF 原图)。请向下滚动各 Task 小节查看对应示意图。下载:实用链接。顾问导读:工程服务。后续:Annex 68。

Figure index (7) · 附图索引(7)

  1. 0 Overview / 总览
  2. T1-A Principle / 原理
  3. T1-B Cycles / 循环家族
  4. T2 Terminology / 术语
  5. T3 Pathway / 策略路径
  6. T4 Specs / 规格测试
  7. T5 Dissemination / 传播

0 · Framework / 框架

Spine: Technologies → Integration → Transition → Specs & testing → Dissemination. Audience: OEMs, end-users, consultants, planners, policy makers.

主线:技术 → 集成 → 转型 → 规格与测试 → 传播。受众:制造商、终端用户、顾问、规划者与政策方。

T1 Tech 技术 → T2 Integ. 集成 → T3 Transit 转型 → T4 Specs 规格/测试 → T5 Share 传播 Supply heat > 100 C 供热温度 > 100 C IEA HPT Annex 58 task spine
Fig. Overview — Annex 58 task spine (self-drawn). 总览图 — Annex 58 五任务主线(自绘)。

Task 1 · Technologies / 技术(HPT-AN58-2)

Takeaway: Catalogue what exists for HTHP systems & components—cycles, fluids, TRL, demos—before any purchase narrative. Snapshot: ~34 technologies, TRL 4–9, ~30 kW–70 MW, max supply ~100–280 °C, indicative ~200–1500 €/kW; ~18 demo cases.

提炼:先盘点高温热泵系统与部件现状(循环、工质、TRL、示范),再谈采购。快照:约 34 项技术、TRL 4–9、约 30 kW–70 MW、最高供热约 100–280°C、示意比投资约 200–1500 €/kW;约 18 个示范案例。

  • HTHP = relevant share of useful heat >100 °C · HTHP = 有用热中相当份额 >100°C
  • Families: single/IHX, economizer, twin, cascade, transcritical, steam/MVR, TDHP · 家族:单级/IHX、经济器、双循环、复叠、跨临界、蒸汽/MVR、热驱动
  • Read supplier sheets as indicative—separate claims vs proven envelopes · 供应商两页卡仅作示意——区分宣称与已验证包络
After Task 1 Fig. 1-1 | 据 Task 1 图 1-1 Source 热源 T_low → Heat pump 热泵 + Work / 功 ↑ Lift / 温升 → Sink 热汇 >100 C HTHP principle | 高温热泵基本原理
Main chart A — Heat-pump principle (after Task 1 Fig. 1-1). 主图 A — 热泵原理(据 Task 1 图 1-1 自绘)。
After Task 1 Figs. 1-2 to 1-5 | 据 Task 1 图 1-2 至 1-5 Single / IHX 单级 ± 内换热器 Economizer 经济器 / 喷液 Twin / Multi 双 / 多循环 Cascade 复叠 LT+HT Transcritical 跨临界 / 焦耳 Steam / MVR 蒸汽 / 再压缩 TDHP / Heat transformer 热驱动热泵 / 热变压器 Cycle / technology families | 循环与技术家族
Main chart B — Cycle / technology families (after Task 1 Figs. 1-2–1-5). 主图 B — 循环与技术家族(据 Task 1 图 1-2~1-5 自绘)。

Task 1 PDF (HPT-AN58-2) · Technology sheets

Task 2 · Integration Concepts / 集成概念(HPT-AN58-3)

Takeaway: Separate where heat connects (integration concept) from which machine (HP concept). Study: 12 processes → ~27 integration points → 3 application buckets → ~15 HP concepts.

提炼:把「热在何处接入」(集成概念)与「用哪类机器」(热泵概念)分开。研究:12 工艺 → 约 27 集成点 → 3 类应用 → 约 15 个热泵概念。

  • Buckets: hot water · steam · large temperature glide · 三类:热水 · 蒸汽 · 大温差 glide
  • Unit operations often share requirements despite different plant layouts · 同类单元操作需求常相近,即便工厂布局不同
After Task 2 Fig. 1-2 | 据 Task 2 图 1-2 Process 工艺/系统 → Integration concept 集成概念 → HP application 热泵应用 HW·Steam·Glide → HP concept 机器概念 12 processes · ~27 points · 15 HP concepts 12 工艺 · 约 27 集成点 · 15 热泵概念 Terminology stack | 术语层级
Main chart — Terminology stack (after Task 2 Fig. 1-2). 主图 — 术语层级(据 Task 2 图 1-2 自绘)。

Task 2 report (HPT-AN58-3)

Task 3 · Applications & Transition / 应用与转型(HPT-AN58-4)

Takeaway: Quick wins help but rarely finish decarbonization. Build a site roadmap: goal → site data → concepts → path—with HTHPs as one package among several.

提炼:易做措施可加速,但很少能单独完成脱碳。场地路线图:目标 → 现场数据 → 概念方案 → 实施路径——HTHP 是一揽子措施之一。

  • Wrong sequence can lock out later HTHP options · 错误排序可能堵死后续高温热泵选项
  • Utility vs process-level integration changes COP and feasibility · 公用工程级 vs 工艺级集成会改变 COP 与可行性
After Task 3 Figs. 1-1 / 1-2 | 据 Task 3 图 1-1、1-2 1. Goal 目标设定 2. Site 现场数据 3. Concepts 概念方案 4. Path 实施路径 Quick wins → utility/process optim. → HTHP → revisit 易做措施 → 公用/工艺优化 → HTHP → 复盘 Strategy path | 脱碳策略路径
Main chart — Strategy path (after Task 3 Figs. 1-1 / 1-2). 主图 — 脱碳策略路径(据 Task 3 图 1-1 / 1-2 自绘)。

Task 3 report (HPT-AN58-4)

Task 4 · Specs & testing / 规格与测试(HPT-AN58-5)

Takeaway: Align tender, FAT/SAT, and guarantees on the same performance story. Prefer performance maps over a single COP; agree how off-design points compare to promises. ~30% of engineering effort often sits before CAPEX decision.

提炼:让招标、FAT/SAT 与担保讲同一套性能故事。优先性能图而非单点 COP;事先约定非设计点如何对照承诺。约 30% 工程量常花在 CAPEX 决策之前。

  • Specify source/sink media, T, flow, operating points early · 尽早明确源/汇介质、温度、流量与工况点
  • FAT (factory) → SAT (site) → guarantee acceptance · 工厂验收 → 现场验收 → 担保验收
After Task 4 Figs. 2-1 / 5-1 | 据 Task 4 图 2-1、5-1 Idea/FS 构思 → Tender 招标 → Design 设计 → FAT 工厂验收 → SAT 现场验收 → Guar. 担保 Performance maps (not a single COP) 性能图(非单点 COP)vs sink/source T & glide Agree off-design comparison rules | 约定非设计点对照规则 Project stages + maps | 项目阶段与性能图
Main chart — Project stages + performance-map idea (after Task 4 Figs. 2-1 / 5-1). 主图 — 项目阶段与性能图概念(据 Task 4 图 2-1 / 5-1 自绘)。

Task 4 report (HPT-AN58-5)

Task 5 · Dissemination / 传播

Takeaway: No standalone Task 5 technical PDF—dissemination is Task 1–4 reports, Final / Executive / 2-page summaries, workshops, HPT Magazine, and the Apr 2024 webinar (230+ attendees).

提炼:无独立 Task 5 技术报告——传播层即 Task 1–4 报告、结题/执行/2 页摘要、工作坊、HPT Magazine,以及 2024-04 结题 webinar(230+ 参会)。

  • Living portal: Project 58 / Annex 58 publications · 持续门户:Project 58 / Annex 58 出版物
  • Continuation: Project / Annex 68 · 延续:Project / Annex 68
Reports 报告 → Workshop 研讨会 → Webinar 网络研讨 → Magazine 杂志 → Audience 受众 No standalone Task 5 technical PDF 无独立 Task 5 技术 PDF Dissemination channels | 传播渠道
Main chart — Dissemination channels (Task 5 overview). 主图 — 传播渠道(Task 5 总览自绘)。

Task 5 page · Publications

On-site advisory spine: T1 · T2 · T3 · T4 · T5. Cycles: Cycles. 站内顾问导读:T1 · T2 · T3 · T4 · T5。循环:循环导读。

Quick FAQs

What is IEA HPT Annex 58?

Annex 58 (2020–2023) mapped high-temperature heat pumps that supply useful heat above about 100 °C across technologies, integration, transition, specifications/testing, and dissemination.

Is this page the official Annex 58 report?

No. It is a bilingual reading guide with self-drawn schematics. Authoritative PDFs and Task pages live on heatpumpingtechnologies.org.

How does Annex 58 relate to Annex 68 and this site’s services?

Annex 68 continues the high-temperature heat-pump work. Site Services pages follow the Annex 58 Task spine (T1–T5) as an advisory reading path, not as a substitute for the TCP reports.

IEA HPT Annex 58

Annex 68 · Services · PDF downloads

© 2026 Open Thermal AI · Founded by Jing Yanrong.